Components
| INTERNA-RAIL® PIPE RAILING SYSTEM |
- All fittings on these pages are for use with 11/2" schedule 40 aluminum pipe, unless noted.
- For additional strength, use schedule 80 pipe and tees for posts or solid dowel insert with schedule 40 pipe.
- Pipe is supplied with a clear anodized, 204-R1 finish.
- Fittings are supplied with a clear anodized, 215-R1 finish.
- Pre-assembled vertical posts can be purchased and shipped with fittings in place.
|
90° ELBOW |
ACUTE ANGLE TEE |
OBTUSE ANGLE TEE |
|
|
|
|
Cast Aluminum |
Schedule 40 |
IR130 |
|
|
Schedule |
Angle Range |
Cast Aluminum |
Schedule 40 |
3°-5° |
IR173.4 |
Schedule 40 |
17°-19° |
IR173.18 |
Schedule 40 |
28°-30° |
IR173.29 |
Schedule 40 |
31°-33° |
IR173.32 |
Schedule 40 |
34°-36° |
IR173.35 |
Schedule 40 |
37°-39° |
IR173.38 |
Schedule 80 |
3°-5° |
IR178.4 |
Schedule 80 |
17°-19° |
IR178.18 |
Schedule 80 |
28°-30° |
IR178.29 |
Schedule 80 |
31°-33° |
IR178.32 |
Schedule 80 |
34°-36° |
IR178.35 |
Schedule 80 |
37°-39° |
IR178.38 |
|
Schedule |
Angle Range |
Cast Aluminum |
Schedule 40 |
3°-5° |
IR174.4 |
Schedule 40 |
17°-19° |
IR174.18 |
Schedule 40 |
28°-30° |
IR174.29 |
Schedule 40 |
31°-33° |
IR174.32 |
Schedule 40 |
34°-36° |
IR174.35 |
Schedule 40 |
37°-39° |
IR174.38 |
Schedule 80 |
3°-5° |
IR179.4 |
Schedule 80 |
17°-19° |
IR179.18 |
Schedule 80 |
28°-30° |
IR179.29 |
Schedule 80 |
31°-33° |
IR179.32 |
Schedule 80 |
34°-36° |
IR179.35 |
Schedule 80 |
37°-39° |
IR179.38 |
|
|
90° ELBOW |
90° CORNER TEE (set of two) |
END CAP |
|
|
|
|
Cast Aluminum |
Schedule 40 |
IR155 |
Schedule 80 |
IR158 |
|
|
Cast Aluminum |
Schedule 40 |
IR159 |
Schedule 80 |
IR159.80 |
|
|
CROSS |
ADJUSTABLE OBTUSE ANGLE TEE |
ADJUSTABLE ACUTE ANGLE TEE |
|
|
|
|
Cast Aluminum |
Set of two IR155 90° Tees. |
IR157 |
Bolts and threaded rivets not included; order separately (page 77) or you may use a through bolt with lock washer and nut.
|
 |
|
|
|
Cast Aluminum |
Schedule 40 |
IR172 |
May be adjusted to stair or ramp angle as needed. Contains Tee and Trunion fittings and hardware.
|
|
|
Cast Aluminum |
Schedule 40 |
IR171 |
May be adjusted to stair or ramp angle as needed. Minimum angle is 10º. Maximum angle is 45º. Contains Tee and Trunion fittings and hardware.
|
|
 |
|
Schedule 40 pipe is suitable for use as horizontal railing or vertical posts. To increase a railing’s load bearing ability, use schedule 80 pipe in fabricating your vertical post assemblies or use schedule 40 pipe in combination with the IR93200 Solid Dowel. |
- After drilling 27/64" diameter hole, tubular rivet is inserted.
- A rivet setting tool is then used to crimp the rivet inside the pipe wall.
- Once in position, the fitting is connected to the vertical pipe with the use of a socket head cap screw.
|
| PIPE |
Pipe Size |
Sch. |
OD |
ID |
t |
6063-T6
Anodized Aluminum |
6063-T6 Satin
Anodized Aluminum |
1-1/2" |
40 |
1.900" |
1.610" |
.145" |
P560 |
P565 |
1-1/2" |
80 |
1.900" |
1.500" |
.200" |
P582 |
P585 |
|
- May be purchased as individual fittings and pipe or assembled
components.
- Designed to allow for easy site assembly and installation of handrail on both new construction or alterations.
- All hardware is stainless steel and anodized aluminum.
|
|
|
| THREADED RIVIT SETTER |
Use with IR9561 |
IR-TS |
For larger jobs, a pneumatic rivet setting tool is available. Contact Wagner for availability.
|
|
|
| THREADED RIVETS |
Anodized Aluminum |
5/8 - 18 x .94" |
IR9561 |
|
|
COVER FLANGE |
SOLID DOWEL |
INSERT COUPLING |
|
|
|
|
|
Pipe Size |
Tube OD |
Extruded Aluminum |
1-1/2" |
1.900" |
SA517 |
5" Long
Friction fit. Set in place with Epoxy.
|
|
SINGLE LOCK SPLICE-LOCK™ |
3M™ SCOTCH-WELD™ EPOXY |
POST BRACKET |
|
|
|
Length |
Aluminum |
Stainless |
3-3/4" |
3319 |
3321 |
6" |
3345 |
3349 |
|
|
SET SCREW
|
Stainless |
3/8 - 16 x 1-7/16" |
IR81913 |
THROUGH BOLT |
Stainless |
5/16 - 18Square Nut |
IR78212 |
5/16 - 18 x 3-1/4" Socket Head Cap Screw |
IR7813 |
Lock Washer for 5/16" Bolt |
9572B |
|
| Applicator Gun with Plunger, 1 50 ml Epoxy and 2 tips |
EPX100 |
| 1 50 ml Epoxy Cartridge Refill and 2 Tips |
EPX100R |
| Plunger |
EP100P |
|
| Meets ADA and ANSI requirements for minimum clearances. May be rotated to any angle. Click here for other brackets. |
|
Cast Aluminum |
Clear Anodized |
IR85KA |
Tumbled Mill |
IR85KM-87 |
- Handrail bracket IR85 can be rotated to any angle for ramps or stairs.
- Provides for 11/2" clearance between
handrail and post or wall.
- Mounts with 5/16" button head bolt and threaded rivet which are provided.
|
|
TOE BOARD EXTRUDED OFFSET BRACKET |
TOE BOARD CORNER SPLICE |
TOE BOARD BRACKET |
|
|
|
|
Aluminum |
1" Wide Aluminum |
IR28610 |
|
|
|
FLANGE |
TOE BOARD BRACKET |
TOE BOARD BRACKET |
|
|
|
|
- 5" x 5" base
- Four 7/16" holes
|
Aluminum |
SR45SBC-8 |
|
|
|
4" BEVELED TOEPLATE |
TOE BOARD CLAMP |
TOE BOARD SPLICE |
|
|
|
|
Aluminum |
24' Lengths |
IR94102 |
|
|
|
TOE BOARD |
EXTRA HEAVY DUTY FASCIA FLANGE |
EXTRUDED FASCIA FLANGE |
|
|
|
| Mill Finish; 16' Length |
|
Aluminum |
1/4" x 4" |
B20340 |
|
| 1-5/8" to center of post Four 11/16" x 1-3/8" slots |
Thickness |
Height |
Width |
Cast Aluminum |
7/16" |
8" |
6" |
SR52HD-8 |
|
111/32" to center of post
Four 7/16" holes
Includes rubber gasket for mounting |
Thickness |
Height |
Width |
Aluminum |
3/8" |
5" |
5" |
SR52E-8 |
|
TOE BOARD CLIP |
ROUND WALL FLANGE |
HEAVY DUTY RECTANGULAR BASE FLANGE |
|
|
|
|
| 9/16" × 1" slot at center for wall mount holes |
Thickness |
Height |
Width |
Cast Aluminum |
5/16" |
2-9/16" |
3-3/4" |
SR43-8 |
|
| Four 9/16" holes for 1/2" mounting bolts |
Thickness |
Height |
Base |
Cast Aluminum |
9/16" |
3-1/2" |
6" x 7-1/2" |
SR48BC-8 |
|
GATE HINGE |
ROUND FLOOR FLANGE |
GATE LATCH & STOP |
|
|
|
|
| Supplied in sets of two – both with springs. Fasten with ¼-20 × ½" Stainless Steel Flat Head Machine Screws not included. |
|
Cast Aluminum |
Six 1/4" holes |
IR100 |
|
| Four 9/16" holes for 1/2" mounting bolts |
Thickness |
Height |
Base Diam. |
Cast Aluminum |
3/8" |
2-5/16" |
4-1/2" |
SR42-8 |
|
Interna-Rail® is designed to meet the requirements of the Americans with Disabilities Act and ANSI A117.1. Refer to page 264 for information on ADAAG requirements. |
|
|
|
|